Welcome to Shanghai HI RUN system control Co., Ltd!

Contact us Collection site Online Message

National Service Hotline 021-63526338
  • Home
  • About Us
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/about/ —— About Us {/dede:channel}
  • Product Center
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Product Center/ —— Product Center {/dede:channel}
  • News Information
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/News Information/ —— News Information {/dede:channel}
  • Engineering Case
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Engineering Case/ —— Engineering Case {/dede:channel}
  • Sales Outlets
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Sales Outlets/ —— Sales Outlets {/dede:channel}
  • Download
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /Download/ —— Download {/dede:channel}
  • Contact Us
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Contact Us/ —— Contact Us {/dede:channel}
  • Online Message

Hot keyword search:

Mining Cable Location:Home> > English > Product Center > Mining Cables > Mining Cable >

Type SHD-GC Three-Conductor Portable Power Cable, CPE Sheath 25kV

Article source:http://www.trcables.com/   author:上海嗨润   Release time:2018-02-02 11:12   Browse times:second

Return:Mining Cable
Type SHD-GC Three-Conductor Portable Power Cable, CPE Sheath 25kV

Applications

These heavy duty cables are designed for applications such as longwall shearers, continuous miners and mobile equipment such as shovels, dredges and drills.

Standards

  • ICEA S-75-381/NEMA WC 58
  • ASTM B 172
  • ASTM B 33
  • CAN/CSA-C22.2 No.96

Construction

Type SHD-GC Three-Conductor Portable Power Cable, CPE Sheath 25kV

  • Conductors: Stranded annealed tinned copper conductor.
  • Conductor Shield:Semi-conducting layer.
  • Insulation:EPR.
  • Insulation Shield:Non-conducting tape + Tinned copper/textile braid.
  • Ground Check Conductor:Tinned copper with a yellow polypropylene insulation.
  • Grounding Conductor:Tinned copper conductor.
  • Sheath: Reinforced extra-heavy-duty Chlorinated Polyethylene(CPE), black. Other sheath materials can be offered upon request.

Options:

Other jacket materials such as CSP/PCP/NBR/PVC are available upon request.

Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.

Mechanical and Thermal Properties

  • Minimum Bending Radius: 8×OD
  • Maximum Operating Temperature: +90℃

Dimensions and Weight:

Construction No. of Strands Grounding Conductor Size Ground Check Conductor Size Nominal Insulation Thickness Nominal Sheath Thickness Nominal Sheath Thickness Nominal Weight Ampacity
No. of cores×AWG/kcmil - AWG/kcmil AWG/kcmil inch mm inch mm inch mm lbs/kft kg/km A
3×1 259 5 8 0.260 6.6 0.265 6.7 2.95 74.9 5290 7872 191
3×1/0 259 4 8 0.260 6.6 0.265 6.7 3.05 77.5 5800 8631 218
3×2/0 329 3 8 0.260 6.6 0.280 7.1 3.20 81.3 6515 9695 249
3×3/0 413 2 8 0.260 6.6 0.280 7.1 3.33 84.6 7215 10737 286
3×4/0 532 1 8 0.260 6.6 0.295 7.5 3.50 88.9 8250 12277 327

Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.